*** Basic Information ***
========================================================================
[Create date] 2011/08/16
------------------------------------------------------------------------
[Program Name] System/Copy
------------------------------------------------------------------------
[Version] 1.03
------------------------------------------------------------------------
[PCB No.] 
------------------------------------------------------------------------
[Interchangeability] X / O
------------------------------------------------------------------------
[Other Firmware Requirements] None
------------------------------------------------------------------------
[PCB Requirements] None
------------------------------------------------------------------------
[Software category] Normal Release
------------------------------------------------------------------------
[Release category] Normal Release
------------------------------------------------------------------------
[Program category] Firmware
------------------------------------------------------------------------
Exported to(language) GEN(all)
[Firmware No.] D0675530E
[File Information]
 File Name         D0675530E.fwu
 File Type         Module for Service
 Size              16.44 MB ( 17238308 byte )
[File Information]
 File Name         D0675530E.rfu
 File Type         Module for Remote Upgrade
 Size              16.45 MB ( 17244416 byte )
------------------------------------------------------------------------
[Production reflection] 2011/09
------------------------------------------------------------------------

========================================================================
*** Note ***
========================================================================
[Note] 

------------------------------------------------------------------------


========================================================================
*** Important Notes ***
========================================================================
[Important Notes] 

------------------------------------------------------------------------


========================================================================
*** Modification History ***
========================================================================
[Modifications made:]
Symptom corrected:
SC870 is triggered and cannot be cleared if the main power switch is 
turned off while data is being written to the Address Book.

------------------------------------------------------------------------
[Modification history]
----------------------------------------
Version 1.02
Symptom corrected: 
1. If the Password Policy is enabled, "Target User Entry ID" 
   and "Target User Code/User Name" are not logged in the CSV file 
   that downloaded via Web Image Monitor and in the 
   Web SmartDeviceMonitor's Access Log List when a user tries and 
   fails due to the password policy to change their password.

----------------------------------------
Version 1.01
Symptom:
The vendor code contained in the controller board Mac address was
updated from "00-00-74" to "00-26-73" (all possible Mac addresses
using the old vendor code have been exhausted).
Symptom corrected:
1.If a user logs back in after their session has timed out, the
  device might stall with the message "Authenticating... Please wait". 
2.The printer application will stall if any of the following
  situations are encountered:
   - A print job is submitted while another print job is already
     being processed by the device.
   - A print job is submitted while the TWAIN driver is scanning.
3.A scan initiated by TWAIN might fail if a print job is already
  being processed by the device.
4.Scan to NCP fails if all of the following conditions met:
   - The destination is specified using the IP address.
   - The Novell server and the device are in different subnets.
   - The subnet routers filter SLP multicasts.
Note: Requires System firmware (version 1.01 or later) and Scanner
firmware (version  1.05 or later).
5.Scan to NCP fails or takes long time to complete if the IPX
  protocol is used and there are more than 2 Novell Directory
  Services (NDS) servers in the netwok hierarchy.
Note: Requires System firmware (version 1.01 or later) and Scanner
firmware (version  1.05 or later).
6.If the device is configured to use "Custom Authentication", logins
  to Web ImageMonitor will be logged as "LDAP Authentication" in the
  Remote Communication Gate S Pro and Web SmartDeviceMonitor Access Logs.


----------------------------------------