Siemens -- Hicom 100 E.pdf

(1814 KB) Pobierz
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01//EN" "http://www.w3.org/TR/html4/strict.dtd">
Hicom 100 E
Hicom 108
Hicom 112
Hicom 118
Hicom 118-2
Service manual
A31003-K16-X001-3-7620
879769251.020.png 879769251.021.png 879769251.022.png
ã
Siemens AG 1999.
All rights reserved.
Subject to availability.
Right of modification reserved.
Issued by
Information and Communication Networks
Hofmannstrasse 51, D-81359 München
Siemens Aktiengesellschaft
Reference No.: A31003-K16-X001-3-7620
Printed in the Federal Republic of Germany.
879769251.023.png 879769251.001.png
Important Information
1
System data
2
Overview of modules
3
Hicom 100 E
Features
Hicom 108
4
Installation
5
Hicom 112
Initial operation
6
Service manual
Administration and maintenance
7
Least Cost Routing (LCR)
8
Maintenance and repair
9
Programming guide
10
Plus products
11
Euroset line 36/Hicom 118-2
12
--
13
--
14
--
15
A31003-K16-X001-3-7620
879769251.002.png 879769251.003.png 879769251.004.png 879769251.005.png 879769251.006.png 879769251.007.png 879769251.008.png 879769251.009.png 879769251.010.png 879769251.011.png 879769251.012.png 879769251.013.png 879769251.014.png 879769251.015.png 879769251.016.png 879769251.017.png
 
Table of Contents
Table of Contents
0
1 Important Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.1 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.1.1 Safety information: Danger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.1.2 Safety information: Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.1.3 Safety information: Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.1.4 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.1.5 Behaviour in emergencies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.1.6 Accident reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.2 Data protection and data security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
2 System data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1 General system description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2 Hardware overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.3 Documentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.4 System types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.5 Hicom 108 system overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.6 Hicom 112 system overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2.7 Hicom 118 system overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.8 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.9 Basic configuration and system expansions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
2.10 System interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
3 Overview of modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1 Table of item code numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2 Overview of configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3.3 Standard extension number plans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
3.3.1 Standard numbering of the MB modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
3.3.2 Extension number plans of the add-on modules . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
3.4 Main module - motherboard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3.5 Add-on modules for system expansions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
3.5.1 SLAS8/4 (subscriber line analogue) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
3.5.2 SLAS16 (subscriber line analogue). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
3.5.3 SLU8 (subscriber line UP0/E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
3.5.4 STLS (subscriber trunk line S 0 ). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
3.5.5 TLA 4/2 (trunk line analogue) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
3.5.6 TLA 8 (trunk line analogue) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
3.6 Function expansions with options bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.6.1 Options adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.6.2 GEE module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.6.3 Serial interface board (SIB) (V.24 connection) . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
3.6.4 STRB control relay module (actuators/sensors) . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1 , Service manual
0-1
879769251.018.png
 
Table of Contents
3.6.5 Fax recognition and DDI module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
3.6.6 ALUM module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
3.6.7 STBG4 module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29
3.7 Function expansions without options bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
3.7.1 EXM/MPPI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
3.7.2 Serial Interface Cable and V.24 adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-32
3.7.3 Coarse protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33
3.8 Power supply (PSU/UPS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
3.9 Main distribution frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.1 Hardware features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.2 ANIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.3 All traffic modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.4 Incoming traffic, general . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.5 Outgoing traffic, general (as of SW 2.0.2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.6 General trunk traffic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.7 Incoming trunk traffic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.8 Outgoing trunk traffic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
4.9 Least cost routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
4.10 Internal traffic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
4.11 Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
4.12 Call charges - call detail recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
4.13 Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
4.14 Measures in the event of a power failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
4.15 Cordless solutions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
4.16 CorNet-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
4.17 Q-Sig networking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
4.18 Euro-ISDN to PBX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
4.19 Euro-ISDN to extension S 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
4.20 Description of feature update in SW 2.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
4.20.1 MSN feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
4.20.1.1 Specific seizure with existing DDI number. . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
4.20.1.2 DDI-specific signalling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
4.20.1.3 MULAP group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
4.20.1.4 Configuration options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
4.20.2 Automatic DTMF switchover after "CONNECT" . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
4.20.3 Enhanced door opener functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
4.20.4 Extending an undialed line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
4.20.5 Group ringing, no answer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
4.20.6 Printout of updated customer data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.1 Selecting the most suitable location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2 Installing the system unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
A31003-K16-X001-3-7620 , 07/99
0-2
Hicom 100 E Version 2.1, Service manual
879769251.019.png
 
Zgłoś jeśli naruszono regulamin